Determination of prohibited, small peptides in urine for sports drug testing by means of nano-liquid chromatography/benchtop quadrupole orbitrap tandem-mass spectrometry.

Thomas A, Walpurgis K, Krug O, Schänzer W, Thevis M

Journal of chromatography. A28 Jul 2012Cited by 42 (Europe PMC)

Summary

The text of this summary is not shown here, because the article license does not allow reuse. Read it at the source (opens in a new tab)

Text rights: Publisher copyright. Results still quote short attributed sentences.

Results from this study8

No result from this study comes from a test of the peptide.

Studies that did not test the peptide alone8

In this study, the peptide was a lab tool or a carrier, part of a mix, or the subject of a lab method. These results are not evidence about taking the peptide.

  1. 01LabNot a test of GHRP-2 aloneEx vivo tissueOther

    In urine, a nanoUHPLC high-resolution MS/MS screening assay for 11 prohibited peptides, including GHRP‑2, reached limits of detection of 2-10 pg/mL.

    In plain wordsIn lab tests on urine, a screening method detected GHRP‑2 at levels as low as 2-10 pg/mL.

    Peptide
    GHRP-2
    Outcome
    Not applicableLimit of detection in urine
    Study

    n: not reported in source

    Urine
    Outcome group
    Analytical methods and detection · Pharmacology

    Measurements

    limit of detection
    2 to 10 pg/mL
    11-peptide assay

    Source sentences

    Summary
    limits of detection (2-10 pg/mL)
    1 context sentence
    Summary · context
    In the present study, a screening assay was developed comprising 11 prohibited peptides (<1.5 kDa) that are sufficiently purified from urine using weak cation exchange with subsequent determination of all substances by means of nanoUHPLC separation coupled to high resolution tandem mass spectrometry.

    In this study, GHRP-2 was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking GHRP-2.

  2. 02LabNot a test of Hexarelin aloneEx vivo tissueOther

    In urine, a nanoUHPLC high-resolution MS/MS screening assay for 11 prohibited peptides, including hexarelin, reached limits of detection of 2-10 pg/mL.

    In plain wordsIn lab tests on urine, a screening method detected hexarelin at levels as low as 2-10 pg/mL.

    Peptide
    Hexarelin
    Outcome
    Not applicableLimit of detection in urine
    Study

    n: not reported in source

    Urine
    Outcome group
    Analytical methods and detection · Pharmacology

    Measurements

    limit of detection
    2 to 10 pg/mL
    11-peptide assay

    Source sentences

    Summary
    limits of detection (2-10 pg/mL)
    1 context sentence
    Summary · context
    In the present study, a screening assay was developed comprising 11 prohibited peptides (<1.5 kDa) that are sufficiently purified from urine using weak cation exchange with subsequent determination of all substances by means of nanoUHPLC separation coupled to high resolution tandem mass spectrometry.

    In this study, Hexarelin was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking Hexarelin.

  3. 03LabNot a test of GHRP-2 aloneEx vivo tissueOther

    In urine, the 11-peptide screening assay, which covers GHRP‑2, had a recovery of 45-95%.

    In plain wordsIn lab tests on urine, the screening method recovered 45-95% of the peptides, GHRP‑2 among them.

    Peptide
    GHRP-2
    Outcome
    Not applicableExtraction recovery from urine
    Study

    n: not reported in source

    Urine
    Outcome group
    Analytical methods and detection · Pharmacology

    Measurements

    recovery
    45 to 95%
    11-peptide assay

    Source sentences

    Summary
    recovery (45-95%)
    1 context sentence
    Summary · context
    In the present study, a screening assay was developed comprising 11 prohibited peptides (<1.5 kDa) that are sufficiently purified from urine using weak cation exchange with subsequent determination of all substances by means of nanoUHPLC separation coupled to high resolution tandem mass spectrometry.

    In this study, GHRP-2 was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking GHRP-2.

  4. 04LabNot a test of Hexarelin aloneEx vivo tissueOther

    In urine, the 11-peptide screening assay, which covers hexarelin, had a recovery of 45-95%.

    In plain wordsIn lab tests on urine, the screening method recovered 45-95% of the peptides, hexarelin among them.

    Peptide
    Hexarelin
    Outcome
    Not applicableExtraction recovery from urine
    Study

    n: not reported in source

    Urine
    Outcome group
    Analytical methods and detection · Pharmacology

    Measurements

    recovery
    45 to 95%
    11-peptide assay

    Source sentences

    Summary
    recovery (45-95%)
    1 context sentence
    Summary · context
    In the present study, a screening assay was developed comprising 11 prohibited peptides (<1.5 kDa) that are sufficiently purified from urine using weak cation exchange with subsequent determination of all substances by means of nanoUHPLC separation coupled to high resolution tandem mass spectrometry.

    In this study, Hexarelin was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking Hexarelin.

  5. 05LabNot a test of GHRP-2 aloneEx vivo tissueOther

    In urine, the 11-peptide screening assay, which covers GHRP‑2, had a precision below 20% at 100 pg/mL.

    In plain wordsIn lab tests on urine, the screening method for GHRP‑2 and other peptides had a precision below 20% at 100 pg/mL.

    Peptide
    GHRP-2
    Outcome
    Not applicableAssay precision in urine
    Study

    n: not reported in source

    Urine
    Outcome group
    Analytical methods and detection · Pharmacology

    Measurements

    precision
    < 20%
    100 pg/mL

    Source sentences

    Summary
    precision (<20% at 100 pg/mL)
    1 context sentence
    Summary · context
    In the present study, a screening assay was developed comprising 11 prohibited peptides (<1.5 kDa) that are sufficiently purified from urine using weak cation exchange with subsequent determination of all substances by means of nanoUHPLC separation coupled to high resolution tandem mass spectrometry.

    In this study, GHRP-2 was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking GHRP-2.

  6. 06LabNot a test of Hexarelin aloneEx vivo tissueOther

    In urine, the 11-peptide screening assay, which covers hexarelin, had a precision below 20% at 100 pg/mL.

    In plain wordsIn lab tests on urine, the screening method for hexarelin and other peptides had a precision below 20% at 100 pg/mL.

    Peptide
    Hexarelin
    Outcome
    Not applicableAssay precision in urine
    Study

    n: not reported in source

    Urine
    Outcome group
    Analytical methods and detection · Pharmacology

    Measurements

    precision
    < 20%
    100 pg/mL

    Source sentences

    Summary
    precision (<20% at 100 pg/mL)
    1 context sentence
    Summary · context
    In the present study, a screening assay was developed comprising 11 prohibited peptides (<1.5 kDa) that are sufficiently purified from urine using weak cation exchange with subsequent determination of all substances by means of nanoUHPLC separation coupled to high resolution tandem mass spectrometry.

    In this study, Hexarelin was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking Hexarelin.

  7. 07LabNot a test of GHRP-2 aloneEx vivo tissueOther

    In urine, the 11-peptide screening assay, which covers GHRP‑2, was linear from 0 to 500 pg/mL.

    In plain wordsIn lab tests on urine, the screening method for GHRP‑2 and other peptides worked across 0-500 pg/mL.

    Peptide
    GHRP-2
    Outcome
    Not applicableAssay linearity range in urine
    Study

    n: not reported in source

    Urine
    Outcome group
    Analytical methods and detection · Pharmacology

    Measurements

    linearity range
    0 to 500 pg/mL
    11-peptide assay

    Source sentences

    Summary
    linearity (0-500 pg/mL)
    1 context sentence
    Summary · context
    In the present study, a screening assay was developed comprising 11 prohibited peptides (<1.5 kDa) that are sufficiently purified from urine using weak cation exchange with subsequent determination of all substances by means of nanoUHPLC separation coupled to high resolution tandem mass spectrometry.

    In this study, GHRP-2 was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking GHRP-2.

  8. 08LabNot a test of Hexarelin aloneEx vivo tissueOther

    In urine, the 11-peptide screening assay, which covers hexarelin, was linear from 0 to 500 pg/mL.

    In plain wordsIn lab tests on urine, the screening method for hexarelin and other peptides worked across 0-500 pg/mL.

    Peptide
    Hexarelin
    Outcome
    Not applicableAssay linearity range in urine
    Study

    n: not reported in source

    Urine
    Outcome group
    Analytical methods and detection · Pharmacology

    Measurements

    linearity range
    0 to 500 pg/mL
    11-peptide assay

    Source sentences

    Summary
    linearity (0-500 pg/mL)
    1 context sentence
    Summary · context
    In the present study, a screening assay was developed comprising 11 prohibited peptides (<1.5 kDa) that are sufficiently purified from urine using weak cation exchange with subsequent determination of all substances by means of nanoUHPLC separation coupled to high resolution tandem mass spectrometry.

    In this study, Hexarelin was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking Hexarelin.

AI wrote and checked these results. AI can make mistakes, so check important results against the source.

Version history

PepBank keeps every version of the data on this study. Status changes from Retraction Watch, Europe PMC and Crossref are listed with their source.

  1. Versions 5 to 19Current

    28 Oct 2026, 02:02 UTC

    The same notice was added 15 times, first on 13 Oct 2026, 21:44 UTC. The status did not change between them.

    Study results updated

  2. Versions 3 to 4

    13 Oct 2026, 16:31 UTC

    The same notice was added 2 times, first on 13 Oct 2026, 16:31 UTC. The status did not change between them.

    Study data updated · source update from Europe PMC

  3. Version 2

    9 Oct 2026, 18:17 UTC

    Study results updated

  4. Version 1

    9 Oct 2026, 03:13 UTC

    First added · source update from Europe PMC

Subjects

Terms as the source lists them.

PepBank is a research reference. Talk to a doctor before you use any peptide.