In pediatric histrelin procedures, implant fracture or counter-incision occurred in 10 procedures (5%).
In plain wordsIn pediatric histrelin procedures, implant fracture or an additional incision occurred in 10 procedures (5%).
- Peptide
- Histrelin
- Outcome
- Not applicableProcedural complications
- Study
n = 73
- Outcome group
- Adverse events · Whole body
- Studied dose
- Dose not stated
Measurements
- Procedures with complications
- 10 procedures
- histrelin implant procedures (fracture or counter-incision)
- Complication rate
- 5%
- histrelin implant procedures
Source sentences
Complications (i.e. implant fracture or need for counter-incision) were noted in 10 of the procedures (5%).
1 context sentence(design, population, supporting numbers)
A retrospective study was performed for histrelin implant procedures done at our institution from 2008 to 2020.