A validated immunopurification LC-HRMS method for GHRHs including CJC‑1295 had a limit of detection of 0.2 ng/mL and a limit of identification of 0.5 ng/mL.
In plain wordsIn lab tests, a urine method could detect CJC‑1295 and related peptides at very low levels.
- Peptide
- CJC-1295 (with DAC)
- Outcome
- Not applicableLimits of detection and identification in urine
- Study
n: not reported in source
Human urine samples- Outcome group
- Analytical methods and detection · Pharmacology
Measurements
- LOD
- 0.2 ng/mL
- magnetic bead immunopurification LC-HRMS
- LOI
- 0.5 ng/mL
- magnetic bead immunopurification LC-HRMS
Source sentences
limit of detection (0.2 ng/mL) and limit of identification (0.5 ng/mL).
1 context sentence(design, population, supporting numbers)
In this work, we have evaluated the suitability of magnetic beads with different supports, binding capacities and affinity chemistries prior analysis of human urine samples by liquid chromatography coupled to high resolution mass spectrometry using a Quadrupole-Orbitrap instrument.
In this study, CJC-1295 (with DAC) was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking CJC-1295 (with DAC).