In adults with type 1 diabetes, rapid insulin-and-pramlintide increased time in range versus rapid insulin alone.
In plain wordsIn adults with type 1 diabetes, rapid insulin-and-pramlintide increased time in range versus rapid insulin alone.
- Peptide
- Pramlintide (Symlin)
- Outcome
- IncreaseTime in range with rapid insulin
- Study
n: not reported in source
- Comparator
- Rapid insulin-alone artificial pancreas
- Analysis
- Primary
- Outcome group
- Glycemic control · Metabolic and weight
- Studied dose
- Dose not stated · 24 hAs given in this study (human).
Measurements
- Time in range (3.9-10.0 mmol/L)
- 84%
- Rapid insulin-and-pramlintide, SD 13%, P=0.0014
- Time in range (3.9-10.0 mmol/L)
- 74%
- Rapid insulin-alone, SD 18%
Source sentences
Compared with the rapid insulin-alone artificial pancreas system, the rapid insulin-and-pramlintide system increased the time in range from 74% (SD 18%) to 84% (13%) (P = 0.0014), whereas the regular insulin-and-pramlintide system did not change the time in range (69% [19%]; P = 0.22).
1 context sentence(design, population, supporting numbers)
We conducted a randomized crossover trial comparing a rapid insulin-alone artificial pancreas with rapid insulin-and-pramlintide and with regular insulin-and-pramlintide artificial pancreas systems in adults with type 1 diabetes.