Skip to content

Study · Not a test of the peptide alone · 2018

3 results

Quantification of protein markers monitoring the pre-analytical effect of blood storage time before plasma isolation using 15 N metabolically labeled recombinant proteins.

Ahn HS, Park SJ, Jung HG, Woo SJ, Lee C

Journal of mass spectrometry : JMS1 Dec 2018Cited by 1 (Europe PMC)

Summary

The text of this summary is not shown here, because the article license does not allow reuse. Read it at the source (opens in a new tab)

Text rights: Publisher copyright. Results still quote short attributed sentences.

Results from this study3

No result from this study comes from a test of the peptide.

Studies that did not test the peptide alone3

In this study, Thymosin beta-4 (human) was a lab tool or a carrier, part of a mix, or the subject of a lab method. These results are not evidence about taking Thymosin beta-4 (human).

  1. 01HumanNot a test of Thymosin beta-4 (human) aloneOther designOther

    In 40 clinical plasma samples, thymosin beta‑4 (TMSB4X) was higher when blood was kept overnight at 4 C than when plasma was prepared within a day.

    In plain wordsIn patient samples, thymosin beta‑4 in plasma was higher when blood stood overnight than when plasma was prepared within a day.

    Outcome
    IncreasePlasma TMSB4X in clinical samples kept overnight at 4 C
    Study

    n = 40

    Outcome group
    Endogenous peptide levels · Whole body

    Measurements

    TMSB4X mean level, plasma prepared within a day
    0.98 μg/mL
    40 clinical samples
    TMSB4X mean level, blood kept overnight at 4°C
    5.36 μg/mL
    40 clinical samples

    Source sentences

    Summary
    Compared with the plasma samples prepared within a day, the level of both PFN1 and TMSB4X increased in the plasma samples prepared from the blood collected the day before and kept overnight at 4°C (0.51 to 3.11 μg/mL for PFN1 and 0.98 to 5.36 μg/mL for TMSB4X in average).
    1 context sentence
    Summary · context
    We further monitored PFN1 and TMSB4X on 40 samples collected for protein diagnostics under a typical clinical study condition.

    In this study, Thymosin beta-4 (human) was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking Thymosin beta-4 (human).

  2. 02HumanNot a test of Thymosin beta-4 (human) aloneOther designOther

    In plasma samples, the amount of thymosin beta‑4 (TMSB4X) increased rapidly with longer storage time of whole blood before plasma preparation.

    In plain wordsThymosin beta‑4 measured in blood plasma rose quickly when blood stood longer before plasma was prepared.

    Outcome
    IncreasePlasma TMSB4X amount versus storage time before plasma preparation
    Study

    n: not reported in source

    Outcome group
    Endogenous peptide levels · Whole body

    Source sentences

    Summary
    The amounts of PFN1 and TMSB4X increased rapidly depending on the storage time between blood collection and plasma preparation.
    1 context sentence
    Summary · context
    In order to account such pre-analytical effects, we performed liquid chromatography multiple reaction monitoring mass spectrometry (LC-MRM-MS) on 15 selected proteins in plasma samples prepared by varying storage time and temperature of whole blood prior to plasma isolation.

    In this study, Thymosin beta-4 (human) was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking Thymosin beta-4 (human).

  3. 03HumanNot a test of Thymosin beta-4 (human) aloneOther designOther

    Relative quantification showed a significant difference (P < 0.05) in thymosin beta‑4 (TMSB4X) among five proteins with varied blood storage.

    In plain wordsThymosin beta‑4 was one of five blood proteins that differed significantly with blood storage conditions.

    Outcome
    Direction not reportedRelative plasma TMSB4X difference with storage
    Study

    n: not reported in source

    Outcome group
    Endogenous peptide levels · Whole body

    Source sentences

    Summary
    Relative quantification further revealed that five proteins including PFN1, S10A8, S10A9, S10A11, and TMSB4X showed significant difference (P < 0.05).
    1 context sentence
    Summary · context
    In order to account such pre-analytical effects, we performed liquid chromatography multiple reaction monitoring mass spectrometry (LC-MRM-MS) on 15 selected proteins in plasma samples prepared by varying storage time and temperature of whole blood prior to plasma isolation.

    In this study, Thymosin beta-4 (human) was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking Thymosin beta-4 (human).

AI wrote and checked these results. AI can make mistakes, so check important results against the source.

Version history

PepBank keeps every version of the data on this study. Status changes from Retraction Watch, Europe PMC and Crossref are listed with their source.

  1. Version 2Current

    13 Oct 2026, 01:52 UTC

    Study results updated

  2. Version 1

    12 Oct 2026, 18:17 UTC

    First added · source update from Europe PMC

Subjects

Terms as the source lists them.

PepBank is a research reference. Talk to a doctor before you use any peptide.