Skip to content

Study · Randomized controlled trial · n = 20 · 2015

7 results

Exenatide in obesity with accelerated gastric emptying: a randomized, pharmacodynamics study.

Acosta A, Camilleri M, Burton D, O'Neill J, Eckert D, Carlson P, Zinsmeister AR

Physiological reports1 Nov 2015Cited by 65 (Europe PMC)

Summary

Obesity is associated with differences in satiety, gastric emptying (GE), gastric volume, and psychological traits. Exenatide, a short-acting glucagon-like peptide 1 (GLP-1) receptor agonist, is associated with variable weight loss. We compared the effects of exenatide, 5 μg, and placebo SQ, twice daily for 30 days on GE of solids and liquids (scintigraphy), satiety (ad libitum buffet meal), satiation (nutrient drink test, maximum tolerated volume [MTV]), and weight loss in 20 participants with documented accelerated GE of solids (T1/2 < 90 min). Exenatide delayed GE of solids (T1/2 [Δ] 86 min relative to placebo, P < 0.001) and reduced calorie intake at buffet meal ([Δ] 129 kcal compared to placebo). Median weight loss was -0.95 kg (IQR -0.7 to -2.1) for exenatide and -0.55 kg (0.3 to -2.1) for placebo (P = 0.23); 80% of exenatide group had documented reduction in weight. In the exenatide treatment group, there was an inverse correlation between gastric emptying T1/2 and MTV (R = -0.548, P = 0.089). The univariate association of weight change with posttreatment MTV was borderline (Rs = 0.43, P = 0.06); in the multiple regression model, posttreatment MTV was associated with weight change (P = 0.047). The effect of the short-acting GLP-1 receptor agonist, exenatide, on GE is associated with the change in food intake, and the latter impacts weight loss in response to exenatide treatment.
CC BYText from Europe PMC. Highlighted sentences are the source of results.

Results from this study7

4 results from studies that gave the peptide. 4 results from people.

  1. 01HumanRandomized controlled trialEfficacy outcome

    In obesity with accelerated gastric emptying, exenatide delayed solid gastric emptying compared with placebo.

    In plain wordsIn obesity with rapid stomach emptying, exenatide slowed solid food emptying compared with placebo.

    Outcome
    IncreaseSolid gastric emptying half-time
    Study

    n = 20

    Comparator
    Placebo
    Outcome group
    Appetite and food intake · Gastrointestinal
    Studied dose
    5 μg twice daily · subcutaneous · 30 daysAs given in this study (human).

    Measurements

    Gastric emptying half-time difference
    86 min
    relative to placebo

    Source sentences

    Summary
    Exenatide delayed GE of solids (T1/2 [Δ] 86 min relative to placebo, P < 0.001) and reduced calorie intake at buffet meal ([Δ] 129 kcal compared to placebo).
    1 context sentence
    Summary · context
    We compared the effects of exenatide, 5 μg, and placebo SQ, twice daily for 30 days on GE of solids and liquids (scintigraphy), satiety (ad libitum buffet meal), satiation (nutrient drink test, maximum tolerated volume [MTV]), and weight loss in 20 participants with documented accelerated GE of solids (T1/2 < 90 min).
  2. 02HumanRandomized controlled trialEfficacy outcome

    In obesity with accelerated gastric emptying, exenatide reduced buffet calorie intake compared with placebo.

    In plain wordsIn obesity with rapid stomach emptying, exenatide reduced buffet calorie intake compared with placebo.

    Outcome
    DecreaseBuffet calorie intake
    Study

    n = 20

    Comparator
    Placebo
    Outcome group
    Appetite and food intake · Metabolic and weight
    Studied dose
    5 μg twice daily · subcutaneous · 30 daysAs given in this study (human).

    Measurements

    Calorie intake reduction
    129 kcal
    compared to placebo

    Source sentences

    Summary
    Exenatide delayed GE of solids (T1/2 [Δ] 86 min relative to placebo, P < 0.001) and reduced calorie intake at buffet meal ([Δ] 129 kcal compared to placebo).
    1 context sentence
    Summary · context
    We compared the effects of exenatide, 5 μg, and placebo SQ, twice daily for 30 days on GE of solids and liquids (scintigraphy), satiety (ad libitum buffet meal), satiation (nutrient drink test, maximum tolerated volume [MTV]), and weight loss in 20 participants with documented accelerated GE of solids (T1/2 < 90 min).
  3. 03HumanRandomized controlled trialEfficacy outcome

    In obesity with accelerated gastric emptying, weight loss did not differ significantly between exenatide and placebo.

    In plain wordsIn obesity with rapid stomach emptying, weight loss did not differ significantly between exenatide and placebo.

    Outcome
    No significant changeWeight loss
    Study

    n = 20

    Comparator
    Placebo
    Outcome group
    Body weight · Metabolic and weight
    Studied dose
    5 μg twice daily · subcutaneous · 30 daysAs given in this study (human).

    Measurements

    Median weight change
    −0.95 kg
    exenatide
    Median weight change
    −0.55 kg
    placebo

    Source sentences

    Summary
    Median weight loss was -0.95 kg (IQR -0.7 to -2.1) for exenatide and -0.55 kg (0.3 to -2.1) for placebo (P = 0.23); 80% of exenatide group had documented reduction in weight.
    1 context sentence
    Summary · context
    We compared the effects of exenatide, 5 μg, and placebo SQ, twice daily for 30 days on GE of solids and liquids (scintigraphy), satiety (ad libitum buffet meal), satiation (nutrient drink test, maximum tolerated volume [MTV]), and weight loss in 20 participants with documented accelerated GE of solids (T1/2 < 90 min).
  4. 04HumanRandomized controlled trialMechanism

    In exenatide-treated participants with obesity, gastric emptying half-time and maximum tolerated volume had a nonsignificant inverse correlation.

    In plain wordsIn exenatide-treated participants with obesity, stomach emptying time and maximum tolerated drink volume had a nonsignificant inverse link.

    Outcome
    No significant changeGastric emptying and maximum tolerated volume correlation
    Study

    n: not reported in source

    Outcome group
    Appetite and food intake · Metabolic and weight
    Studied dose
    5 μg twice daily · subcutaneous · 30 daysAs given in this study (human).

    Measurements

    Correlation coefficient
    −0.548 R
    gastric emptying half-time versus MTV

    Source sentences

    Summary
    In the exenatide treatment group, there was an inverse correlation between gastric emptying T1/2 and MTV (R = -0.548, P = 0.089).
    1 context sentence
    Summary · context
    We compared the effects of exenatide, 5 μg, and placebo SQ, twice daily for 30 days on GE of solids and liquids (scintigraphy), satiety (ad libitum buffet meal), satiation (nutrient drink test, maximum tolerated volume [MTV]), and weight loss in 20 participants with documented accelerated GE of solids (T1/2 < 90 min).

Studies that did not test the peptide alone3

In this study, Exenatide (exendin-4) was a lab tool or a carrier, part of a mix, or the subject of a lab method. These results are not evidence about taking Exenatide (exendin-4).

  1. 05HumanNot a test of Exenatide (exendin-4) aloneRandomized controlled trialEfficacy outcome

    In obesity with accelerated gastric emptying, 80% of the exenatide group had documented weight reduction, and the placebo group also lost weight.

    In plain wordsIn obesity with rapid stomach emptying, 80% of the exenatide group lost weight, and the placebo group also lost weight.

    Outcome
    DecreaseWeight reduction responder proportion
    Study

    n: not reported in source

    Outcome group
    Body weight · Metabolic and weight

    Measurements

    Weight reduction responders
    80%
    exenatide group

    Source sentences

    Summary
    Median weight loss was -0.95 kg (IQR -0.7 to -2.1) for exenatide and -0.55 kg (0.3 to -2.1) for placebo (P = 0.23); 80% of exenatide group had documented reduction in weight.
    1 context sentence
    Summary · context
    We compared the effects of exenatide, 5 μg, and placebo SQ, twice daily for 30 days on GE of solids and liquids (scintigraphy), satiety (ad libitum buffet meal), satiation (nutrient drink test, maximum tolerated volume [MTV]), and weight loss in 20 participants with documented accelerated GE of solids (T1/2 < 90 min).

    In this study, Exenatide (exendin-4) was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking Exenatide (exendin-4).

  2. 06HumanNot a test of Exenatide (exendin-4) aloneRandomized controlled trialMechanism

    In the obesity study, weight change had a borderline univariate association with post-treatment maximum tolerated volume.

    In plain wordsIn the obesity study, weight change had a borderline link with maximum tolerated drink volume in univariate analysis.

    Outcome
    No significant changeUnivariate weight change and maximum tolerated volume association
    Study

    n: not reported in source

    Outcome group
    Appetite and food intake · Metabolic and weight

    Measurements

    Correlation coefficient
    0.43 Rs
    weight change versus posttreatment MTV

    Source sentences

    Summary
    The univariate association of weight change with posttreatment MTV was borderline (Rs = 0.43, P = 0.06);
    1 context sentence
    Summary · context
    We compared the effects of exenatide, 5 μg, and placebo SQ, twice daily for 30 days on GE of solids and liquids (scintigraphy), satiety (ad libitum buffet meal), satiation (nutrient drink test, maximum tolerated volume [MTV]), and weight loss in 20 participants with documented accelerated GE of solids (T1/2 < 90 min).

    In this study, Exenatide (exendin-4) was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking Exenatide (exendin-4).

  3. 07HumanNot a test of Exenatide (exendin-4) aloneRandomized controlled trialMechanism

    In the obesity study, post-treatment maximum tolerated volume was associated with weight change in multiple regression.

    In plain wordsIn the obesity study, maximum tolerated drink volume was linked to weight change after statistical adjustment.

    Outcome
    Not applicableAdjusted weight change and maximum tolerated volume association
    Study

    n: not reported in source

    Outcome group
    Appetite and food intake · Metabolic and weight

    Source sentences

    Summary
    in the multiple regression model, posttreatment MTV was associated with weight change (P = 0.047).
    1 context sentence
    Summary · context
    We compared the effects of exenatide, 5 μg, and placebo SQ, twice daily for 30 days on GE of solids and liquids (scintigraphy), satiety (ad libitum buffet meal), satiation (nutrient drink test, maximum tolerated volume [MTV]), and weight loss in 20 participants with documented accelerated GE of solids (T1/2 < 90 min).

    In this study, Exenatide (exendin-4) was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking Exenatide (exendin-4).

AI wrote and checked these results. AI can make mistakes, so check important results against the source.

Registered trials1

Trials this study reports on, or that list this study as a reference. Registry data from ClinicalTrials.gov.

1 trial · 1 completed · 1 with posted results · source ClinicalTrials.gov (opens in a new tab)

CompletedPhase 4Results postedNCT02160990

Effect of Exenatide in Obese Patients With Accelerated Gastric Emptying

Mayo Clinicn = 20Jun 2014 to Mar 2015

Obesity

Version history

PepBank keeps every version of the data on this study. Status changes from Retraction Watch, Europe PMC and Crossref are listed with their source.

  1. Version 2Current

    22 Oct 2026, 02:26 UTC

    Study results updated

  2. Version 1

    21 Oct 2026, 18:59 UTC

    First added · source update from Europe PMC

Subjects

Terms as the source lists them.

PepBank is a research reference. Talk to a doctor before you use any peptide.