Expanded test method for peptides >2 kDa employing immunoaffinity purification and LC-HRMS/MS.

Thomas A, Walpurgis K, Tretzel L, Brinkkötter P, Fichant E, Delahaut P, Schänzer W, Thevis M

Drug testing and analysis18 Sept 2015Cited by 31 (Europe PMC)

Summary

The text of this summary is not shown here, because the article license does not allow reuse. Read it at the source (opens in a new tab)

Text rights: Publisher copyright. Results still quote short attributed sentences.

Results from this study6

No result from this study comes from a test of the peptide.

Studies that did not test the peptide alone6

In this study, the peptide was a lab tool or a carrier, part of a mix, or the subject of a lab method. These results are not evidence about taking the peptide.

  1. 01LabNot a test of Sermorelin aloneOther designOther

    An immunoaffinity LC-HRMS/MS method for peptides above 2 kDa, including sermorelin, had recovery of 11-69%.

    In plain wordsA lab method recovered 11 to 69 percent of the target peptides, which include sermorelin.

    Peptide
    Sermorelin
    Outcome
    Not applicableRecovery
    Study

    n: not reported in source

    Outcome group
    Analytical methods and detection · Pharmacology

    Measurements

    Recovery
    11 to 69%
    target peptides

    Source sentences

    Summary
    recovery (11-69%), linearity, imprecision (<25%), limit of detection (5-100 pg in urine, 0.1-2 ng in plasma), and ion suppression.
    1 context sentence
    Summary · context
    Such peptides have been used to manipulate several potential performance-enhancing processes in the athlete's body and include for example growth hormone releasing hormones (sermorelin, CJC-1293, CJC-1295, tesamorelin)

    In this study, Sermorelin was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking Sermorelin.

  2. 02LabNot a test of Sermorelin aloneOther designOther

    The method had imprecision below 25%.

    In plain wordsThe lab method gave repeatable results, with variation below 25 percent.

    Peptide
    Sermorelin
    Outcome
    Not applicableImprecision
    Study

    n: not reported in source

    Outcome group
    Analytical methods and detection · Pharmacology

    Measurements

    Imprecision
    < 25%
    target peptides

    Source sentences

    Summary
    imprecision (<25%), limit of detection (5-100 pg in urine, 0.1-2 ng in plasma), and ion suppression.
    1 context sentence
    Summary · context
    Such peptides have been used to manipulate several potential performance-enhancing processes in the athlete's body and include for example growth hormone releasing hormones (sermorelin, CJC-1293, CJC-1295, tesamorelin)

    In this study, Sermorelin was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking Sermorelin.

  3. 03LabNot a test of Sermorelin aloneOther designOther

    The method had limits of detection of 5-100 pg in urine for the target peptides, which include sermorelin.

    In plain wordsThe lab method detected the target peptides, including sermorelin, in urine at 5 to 100 pg.

    Peptide
    Sermorelin
    Outcome
    Not applicableLimit of detection in urine
    Study

    n: not reported in source

    Outcome group
    Analytical methods and detection · Pharmacology

    Measurements

    LOD
    5 to 100 pg
    target peptides in urine

    Source sentences

    Summary
    limit of detection (5-100 pg in urine, 0.1-2 ng in plasma), and ion suppression.
    1 context sentence
    Summary · context
    Such peptides have been used to manipulate several potential performance-enhancing processes in the athlete's body and include for example growth hormone releasing hormones (sermorelin, CJC-1293, CJC-1295, tesamorelin)

    In this study, Sermorelin was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking Sermorelin.

  4. 04LabNot a test of Sermorelin aloneOther designOther

    The method had limits of detection of 0.1-2 ng in plasma for the target peptides, which include sermorelin.

    In plain wordsThe lab method detected the target peptides, including sermorelin, in plasma at 0.1 to 2 ng.

    Peptide
    Sermorelin
    Outcome
    Not applicableLimit of detection in plasma
    Study

    n: not reported in source

    Outcome group
    Analytical methods and detection · Pharmacology

    Measurements

    LOD
    0.1 to 2 ng
    target peptides in plasma

    Source sentences

    Summary
    0.1-2 ng in plasma), and ion suppression.
    1 context sentence
    Summary · context
    Such peptides have been used to manipulate several potential performance-enhancing processes in the athlete's body and include for example growth hormone releasing hormones (sermorelin, CJC-1293, CJC-1295, tesamorelin)

    In this study, Sermorelin was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking Sermorelin.

  5. 05LabNot a test of MGF / PEG-MGF aloneOther designOther

    An immunoaffinity and LC-HRMS/MS method for peptides, including MGF forms, was applicable to blood and urine samples.

    In plain wordsIn lab tests, the method worked on both blood and urine samples for peptide drugs, including MGF forms.

    Outcome
    Not applicableApplicability of the test method to blood and urine
    Study

    n: not reported in source

    Outcome group
    Analytical methods and detection · Pharmacology

    Source sentences

    Summary
    The method was shown to be applicable to blood and urine samples, which represent the most common doping control specimens.

    In this study, MGF / PEG-MGF was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking MGF / PEG-MGF.

  6. 06LabNot a test of MGF / PEG-MGF aloneOther designOther

    The method was validated for specificity, recovery (11-69%), linearity, imprecision (<25%), limit of detection and ion suppression across the target peptides, including MGF forms.

    In plain wordsIn lab tests, the method was validated for the peptides it covers, including MGF forms, with recovery of 11-69%.

    Outcome
    Not applicableValidation parameters of the test method
    Study

    n: not reported in source

    Outcome group
    Analytical methods and detection · Pharmacology

    Measurements

    Recovery
    11 to 69%
    target analytes
    Imprecision
    < 25%
    target analytes
    Limit of detection
    5 to 100 pg
    urine
    Limit of detection
    0.1 to 2 ng
    plasma

    Source sentences

    Summary
    The method was validated considering the parameters specificity, recovery (11-69%), linearity, imprecision (<25%), limit of detection (5-100 pg in urine, 0.1-2 ng in plasma), and ion suppression.

    In this study, MGF / PEG-MGF was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking MGF / PEG-MGF.

AI wrote and checked these results. AI can make mistakes, so check important results against the source.

Version history

PepBank keeps every version of the data on this study. Status changes from Retraction Watch, Europe PMC and Crossref are listed with their source.

  1. Versions 25 to 48Current

    28 Oct 2026, 02:04 UTC

    The same notice was added 24 times, first on 13 Oct 2026, 21:43 UTC. The status did not change between them.

    Study results updated

  2. Version 24

    13 Oct 2026, 16:31 UTC

    Study data updated · source update from Europe PMC

  3. Versions 4 to 23

    13 Oct 2026, 14:22 UTC

    The same notice was added 20 times, first on 9 Oct 2026, 18:17 UTC. The status did not change between them.

    Study results updated

  4. Versions 2 to 3

    9 Oct 2026, 03:13 UTC

    The same notice was added 2 times, first on 9 Oct 2026, 03:13 UTC. The status did not change between them.

    Study data updated · source update from Europe PMC

  5. Version 1

    9 Oct 2026, 03:13 UTC

    First added · source update from Europe PMC

Subjects

Terms as the source lists them.

PepBank is a research reference. Talk to a doctor before you use any peptide.