In volunteers, radial artery diameter before ischemia-reperfusion did not differ between exenatide and placebo.
In plain wordsIn volunteers, radial artery diameter before ischemia-reperfusion did not differ between exenatide and placebo.
- Peptide
- Exenatide (exendin-4)
- Outcome
- No significant changePre-IR radial artery diameter
- Study
n = 20
- Comparator
- Placebo
- Outcome group
- Vascular function · Cardiovascular
- Studied dose
- 10 μg · subcutaneousAs given in this study (human).
Source sentences
Pre-IR radial artery diameter, FMD, and baseline radial artery diameter after IR injury were similar between 2 groups (P=no significant difference).
2 context sentences(design, population, supporting numbers)
In a double-blind, placebo-controlled, crossover design, 20 volunteers were randomly assigned to 2 groups: subcutaneous exenatide (10 μg) or placebo administration.
At 30 minutes after the study drug administration, endothelium-dependent flow-mediated dilatation (FMD) of the radial artery was measured before and after IR (15 minutes of ischemia at the level of the brachial artery followed by 15 minutes of reperfusion) injury.