After pancreaticoduodenectomy, 24-hour output was 208.6+/-41.3 ml after lanreotide versus 253.9+/-72.4 ml after placebo, without a significant reduction.
In plain wordsAfter pancreatic surgery, 24-hour pancreatic output did not decrease significantly with lanreotide compared with placebo.
- Peptide
- Lanreotide
- Outcome
- No significant change24-hour pancreatic output
- Study
n = 7
- Comparator
- placebo
- Outcome group
- Gastrointestinal function · Gastrointestinal
- Studied dose
- 0.5 mg single dose · subcutaneousAs given in this study (human).
Measurements
- 24-h pancreatic output volume (mean)
- 208.6 ml
- after lanreotide
- 24-h pancreatic output volume (+/- value)
- 41.3 ml
- after lanreotide
- 24-h pancreatic output volume (mean)
- 253.9 ml
- after placebo
- 24-h pancreatic output volume (+/- value)
- 72.4 ml
- after placebo
Source sentences
In the seven patients completing the study, the 24-h output volume was 208.6+/-41.3 and 253.9+/-72.4 ml after lanreotide and placebo, respectively.
2 context sentences(design, population, supporting numbers)
Lanreotide induced a statistically significant reduction in the output volume with respect to placebo in the first 6 hours after administration, but not thereafter.
The volume and composition of pancreatic secretion were evaluated after one single subcutaneous injection of lanreotide 0.5 mg or placebo in a randomised, double-blind cross-over trial.