Two methods for the measurement of the dissociation pressure of a crystalline hydrate.

Crocker LS, Varsolona RJ, McCauley JA

Journal of pharmaceutical and biomedical analysis1 Jul 1997Cited by 1 (Europe PMC)

Summary

The text of this summary is not shown here, because the article license does not allow reuse. Read it at the source (opens in a new tab)

Text rights: Publisher copyright. Results still quote short attributed sentences.

Results from this study1

No result from this study comes from a test of the peptide.

Studies that did not test the peptide alone1

In this study, MK-677 (ibutamoren) was a lab tool or a carrier, part of a mix, or the subject of a lab method. These results are not evidence about taking MK-677 (ibutamoren).

  1. 01LabNot a test of MK-677 (ibutamoren) aloneIn vitro (cell-free)Other

    In laboratory tests of MK-0677 hydrates, the two dissociation pressure methods gave similar results.

    In plain wordsIn lab tests of MK-0677 hydrates, the two dissociation pressure methods gave similar results.

    Outcome
    No significant changeAgreement of dissociation pressure methods
    Study

    n: not reported in source

    Crystalline MK-0677 hydrates
    Comparator
    Infrared spectroscopy versus differential scanning calorimetry
    Outcome group
    Peptide structure and chemistry · Pharmacology

    Source sentences

    Summary
    The methods give similar results for the system of interest.
    3 context sentences
    Summary · context
    Two methods for the measurement of the characteristic dissociation pressures of a system containing water vapor and two different crystalline hydrates of the pharmaceutical compound MK-0677 are described.
    Summary · context
    One method involves the spectroscopic determination of water in gases equilibrated with the solids at controlled temperatures, using an infrared spectrometer.
    Summary · context
    The second method utilized the extrapolated onset temperature of the transition from one hydrate to the other at controlled humidities, as observed by differential scanning calorimetry.

    In this study, MK-677 (ibutamoren) was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking MK-677 (ibutamoren).

AI wrote and checked these results. AI can make mistakes, so check important results against the source.

Version history

PepBank keeps every version of the data on this study. Status changes from Retraction Watch, Europe PMC and Crossref are listed with their source.

  1. Version 2Current

    14 Oct 2026, 05:02 UTC

    Study results updated

  2. Version 1

    14 Oct 2026, 01:46 UTC

    First added · source update from Europe PMC

Subjects

Terms as the source lists them.

PepBank is a research reference. Talk to a doctor before you use any peptide.