Skip to content

Study · Not a test of the peptide alone · 1997

6 results

Determination of a novel growth hormone secretagogue (MK-677) in human plasma at picogram levels by liquid chromatography with atmospheric pressure chemical ionization tandem mass spectrometry.

Constanzer ML, Chavez-Eng CM, Matuszewski BK

Journal of chromatography. B, Biomedical sciences and applications1 May 1997Cited by 11 (Europe PMC)

Summary

The text of this summary is not shown here, because the article license does not allow reuse. Read it at the source (opens in a new tab)

Text rights: Publisher copyright. Results still quote short attributed sentences.

Results from this study6

No result from this study comes from a test of the peptide.

Studies that did not test the peptide alone6

In this study, MK-677 (ibutamoren) was a lab tool or a carrier, part of a mix, or the subject of a lab method. These results are not evidence about taking MK-677 (ibutamoren).

  1. 01LabNot a test of MK-677 (ibutamoren) aloneIn vitro (cell-free)Other

    In laboratory tests, the MK‑677 plasma assay was validated over 0.1 to 100 ng/ml.

    In plain wordsIn lab tests, the MK‑677 plasma assay was validated over 0.1 to 100 ng/ml.

    Outcome
    Not applicableValidated concentration range
    Study

    n: not reported in source

    Human plasma assay
    Outcome group
    Analytical methods and detection · Pharmacology

    Measurements

    Validated concentration range
    0.1 to 100 ng/ml
    Human plasma

    Source sentences

    Summary
    The assay was validated in human plasma in the concentration range of 0.1 to 100 ng/ml, and the limit of quantification (LOQ) was 0.1 ng/ml.
    2 context sentences
    Summary · context
    The method is based on high-performance liquid chromatography (HPLC) with tandem mass spectrometric (MS-MS) detection.
    Summary · context
    The analyte and internal standard (II) were isolated from the basified plasma using a liquid-liquid extraction with methyl-tert.-butyl ether (MTBE).

    In this study, MK-677 (ibutamoren) was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking MK-677 (ibutamoren).

  2. 02LabNot a test of MK-677 (ibutamoren) aloneIn vitro (cell-free)Other

    In laboratory tests, the MK‑677 plasma assay had a limit of quantification of 0.1 ng/ml.

    In plain wordsIn lab tests, the MK‑677 plasma assay measured concentrations as low as 0.1 ng/ml.

    Outcome
    Not applicableLimit of quantification
    Study

    n: not reported in source

    Human plasma assay
    Outcome group
    Analytical methods and detection · Pharmacology

    Measurements

    Limit of quantification
    0.1 ng/ml
    Human plasma

    Source sentences

    Summary
    The assay was validated in human plasma in the concentration range of 0.1 to 100 ng/ml, and the limit of quantification (LOQ) was 0.1 ng/ml.
    2 context sentences
    Summary · context
    The method is based on high-performance liquid chromatography (HPLC) with tandem mass spectrometric (MS-MS) detection.
    Summary · context
    The analyte and internal standard (II) were isolated from the basified plasma using a liquid-liquid extraction with methyl-tert.-butyl ether (MTBE).

    In this study, MK-677 (ibutamoren) was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking MK-677 (ibutamoren).

  3. 03LabNot a test of MK-677 (ibutamoren) aloneIn vitro (cell-free)Other

    In laboratory tests, MK‑677 assay coefficients of variation were less than 7% across the standard curve.

    In plain wordsIn lab tests, MK‑677 assay coefficients of variation were less than 7% across the standard curve.

    Outcome
    Not applicableAssay precision
    Study

    n: not reported in source

    Human plasma assay
    Outcome group
    Analytical methods and detection · Pharmacology

    Measurements

    Coefficient of variation
    < 7%
    All standard curve concentrations

    Source sentences

    Summary
    The precision of the assay, as expressed as coefficients of variation (C.V.,%) was less than 7% at all concentrations within the standard curve range, with adequate assay specificity and accuracy.
    2 context sentences
    Summary · context
    The method is based on high-performance liquid chromatography (HPLC) with tandem mass spectrometric (MS-MS) detection.
    Summary · context
    The analyte and internal standard (II) were isolated from the basified plasma using a liquid-liquid extraction with methyl-tert.-butyl ether (MTBE).

    In this study, MK-677 (ibutamoren) was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking MK-677 (ibutamoren).

  4. 04LabNot a test of MK-677 (ibutamoren) aloneIn vitro (cell-free)Other

    In laboratory tests, the MK‑677 plasma assay had adequate specificity.

    In plain wordsIn lab tests, the MK‑677 plasma assay had adequate specificity.

    Outcome
    Not applicableAssay specificity
    Study

    n: not reported in source

    Human plasma assay
    Outcome group
    Analytical methods and detection · Pharmacology

    Source sentences

    Summary
    The precision of the assay, as expressed as coefficients of variation (C.V.,%) was less than 7% at all concentrations within the standard curve range, with adequate assay specificity and accuracy.
    2 context sentences
    Summary · context
    The method is based on high-performance liquid chromatography (HPLC) with tandem mass spectrometric (MS-MS) detection.
    Summary · context
    The analyte and internal standard (II) were isolated from the basified plasma using a liquid-liquid extraction with methyl-tert.-butyl ether (MTBE).

    In this study, MK-677 (ibutamoren) was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking MK-677 (ibutamoren).

  5. 05LabNot a test of MK-677 (ibutamoren) aloneIn vitro (cell-free)Other

    In laboratory tests, the MK‑677 plasma assay had adequate accuracy.

    In plain wordsIn lab tests, the MK‑677 plasma assay had adequate accuracy.

    Outcome
    Not applicableAssay accuracy
    Study

    n: not reported in source

    Human plasma assay
    Outcome group
    Analytical methods and detection · Pharmacology

    Source sentences

    Summary
    The precision of the assay, as expressed as coefficients of variation (C.V.,%) was less than 7% at all concentrations within the standard curve range, with adequate assay specificity and accuracy.
    2 context sentences
    Summary · context
    The method is based on high-performance liquid chromatography (HPLC) with tandem mass spectrometric (MS-MS) detection.
    Summary · context
    The analyte and internal standard (II) were isolated from the basified plasma using a liquid-liquid extraction with methyl-tert.-butyl ether (MTBE).

    In this study, MK-677 (ibutamoren) was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking MK-677 (ibutamoren).

  6. 06LabNot a test of MK-677 (ibutamoren) aloneIn vitro (cell-free)Other

    The MK‑677 assay had sufficient sensitivity to map the pharmacokinetic time-course after a single oral dose.

    In plain wordsIn lab tests, the MK‑677 assay had sufficient sensitivity to map its pharmacokinetic time-course after a single oral dose.

    Outcome
    Not applicablePharmacokinetic mapping sensitivity
    Study

    n: not reported in source

    Human plasma assay
    Outcome group
    Analytical methods and detection · Pharmacology

    Source sentences

    Summary
    The HPLC-MS-MS method provided sufficient sensitivity to completely map the pharmacokinetic time-course following a single 5-mg oral dose of I.
    2 context sentences
    Summary · context
    The method is based on high-performance liquid chromatography (HPLC) with tandem mass spectrometric (MS-MS) detection.
    Summary · context
    The analyte and internal standard (II) were isolated from the basified plasma using a liquid-liquid extraction with methyl-tert.-butyl ether (MTBE).

    In this study, MK-677 (ibutamoren) was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking MK-677 (ibutamoren).

AI wrote and checked these results. AI can make mistakes, so check important results against the source.

Version history

PepBank keeps every version of the data on this study. Status changes from Retraction Watch, Europe PMC and Crossref are listed with their source.

  1. Version 2Current

    14 Oct 2026, 05:02 UTC

    Study results updated

  2. Version 1

    14 Oct 2026, 01:46 UTC

    First added · source update from Europe PMC

Subjects

Terms as the source lists them.

PepBank is a research reference. Talk to a doctor before you use any peptide.