In hip replacement patients receiving dextran, mean blood loss did not differ significantly between desmopressin and placebo (P > 0.05).
In plain wordsIn hip replacement patients receiving dextran, blood loss did not differ significantly between desmopressin and placebo.
- Peptide
- Desmopressin
- Outcome
- No significant changeMean blood loss
- Study
n = 79
- Comparator
- Placebo
- Outcome group
- Bleeding and clotting · Whole body
- Studied dose
- 0.3 microgram/kg · infusionAs given in this study (human).
Source sentences
There were no statistically significant differences (P > 0.05) in mean blood loss or transfusion requirements between the placebo and the desmopressin group.
2 context sentences(design, population, supporting numbers)
The blood loss-reducing effect of desmopressin during dextran therapy was studied in a double-blind fashion in 79 elderly but otherwise healthy patients with preoperative normal bleeding time undergoing total hip replacement for primary coxarthrosis.
An infusion of desmopressin (0.3 microgram/kg body weight) or placebo was randomly administered immediately after administration of spinal anaesthesia and six hours later.