In hip replacement patients, intraoperative blood loss did not differ significantly between desmopressin and placebo.
In plain wordsIn hip replacement patients, intraoperative blood loss did not differ significantly between desmopressin and placebo.
- Peptide
- Desmopressin
- Outcome
- No significant changeIntraoperative blood loss
- Study
n = 50
- Comparator
- Placebo
- Outcome group
- Bleeding and clotting · Cardiovascular
- Studied dose
- two doses of 0.3 micrograms/kg BWAs given in this study (human).
Source sentences
Intraoperative blood loss and drainage loss did not differ significantly between groups, but desmopressin reduced the mean total blood loss (calculated from hemoglobin decrease and blood transfusions) by 310 mL (P less than 0.05).
1 context sentence(design, population, supporting numbers)
50 patients undergoing elective total hip replacement under epidural anesthesia and dextran infusion were given two doses of the vasopressin analogue desmopressin 0.3 micrograms/kg BW or placebo in a double-blinded randomized prospective study.