Skip to content

Study · Not a test of the peptide alone · 2021

8 results

Ultra-Fast Computation of Excited-States Spectra for Large Systems: Ultraviolet and Fluorescence Spectra of Proteins.

Liu Y, Xu J, Han L, Liu Q, Yang Y, Li Z, Lu Z, Zhang H, Guo T, Liu Q

Interdisciplinary sciences, computational life sciences13 Nov 2020Cited by 3 (Europe PMC)

Summary

The text of this summary is not shown here, because the article license does not allow reuse. Read it at the source (opens in a new tab)

Text rights: Publisher copyright. Results still quote short attributed sentences.

Results from this study8

No result from this study comes from a test of the peptide.

Studies that did not test the peptide alone8

In this study, the peptide was a lab tool or a carrier, part of a mix, or the subject of a lab method. These results are not evidence about taking the peptide.

  1. 01Computer modelNot a test of GHRP-6 aloneIn silicoOther

    In computer calculations including GHRP‑6, wB97XD3 excitation spectra agreed well with experiments.

    In plain wordsComputer calculations including GHRP‑6 produced excitation spectra that agreed well with experiments.

    Peptide
    GHRP-6
    Outcome
    Not applicableExcitation spectrum agreement
    Study

    n: not reported in source

    Outcome group
    Analytical methods and detection · Pharmacology

    Source sentences

    Summary
    Three different Hartree-Fock components functionals (wB97XD3: 51%, LC-BLYP: 53%, wB97X: 57%) were used to calculate the excitation spectra, and the results calculated by wB97XD3 functional well agree with the experiments.
    1 context sentence
    Summary · context
    A workable approach named xTB-sTDDFT was selected to investigate the excited-state spectra of oxytocin (135 atoms), GHRP-6 (120 atoms) and insulin (793 atoms).

    In this study, GHRP-6 was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking GHRP-6.

  2. 02Computer modelNot a test of Oxytocin aloneIn silicoOther

    In computer calculations including oxytocin, wB97XD3 excitation spectra agreed well with experiments.

    In plain wordsComputer calculations including oxytocin produced excitation spectra that agreed well with experiments.

    Peptide
    Oxytocin
    Outcome
    Not applicableExcitation spectrum agreement
    Study

    n: not reported in source

    Outcome group
    Analytical methods and detection · Pharmacology

    Source sentences

    Summary
    Three different Hartree-Fock components functionals (wB97XD3: 51%, LC-BLYP: 53%, wB97X: 57%) were used to calculate the excitation spectra, and the results calculated by wB97XD3 functional well agree with the experiments.
    1 context sentence
    Summary · context
    A workable approach named xTB-sTDDFT was selected to investigate the excited-state spectra of oxytocin (135 atoms), GHRP-6 (120 atoms) and insulin (793 atoms).

    In this study, Oxytocin was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking Oxytocin.

  3. 03Computer modelNot a test of GHRP-6 aloneIn silicoOther

    In computer calculations including GHRP‑6, computation time decreased by more than 80%.

    In plain wordsComputer calculations including GHRP‑6 reduced computation time by more than 80%.

    Peptide
    GHRP-6
    Outcome
    DecreaseComputation time
    Study

    n: not reported in source

    Outcome group
    Analytical methods and detection · Pharmacology

    Source sentences

    Summary
    It's a deep impression that computed time cost reduced by more than 80%.
    1 context sentence
    Summary · context
    A workable approach named xTB-sTDDFT was selected to investigate the excited-state spectra of oxytocin (135 atoms), GHRP-6 (120 atoms) and insulin (793 atoms).

    In this study, GHRP-6 was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking GHRP-6.

  4. 04Computer modelNot a test of Oxytocin aloneIn silicoOther

    In computer calculations including oxytocin, computation time decreased by more than 80%.

    In plain wordsComputer calculations including oxytocin reduced computation time by more than 80%.

    Peptide
    Oxytocin
    Outcome
    DecreaseComputation time
    Study

    n: not reported in source

    Outcome group
    Analytical methods and detection · Pharmacology

    Source sentences

    Summary
    It's a deep impression that computed time cost reduced by more than 80%.
    1 context sentence
    Summary · context
    A workable approach named xTB-sTDDFT was selected to investigate the excited-state spectra of oxytocin (135 atoms), GHRP-6 (120 atoms) and insulin (793 atoms).

    In this study, Oxytocin was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking Oxytocin.

  5. 05Computer modelNot a test of GHRP-6 aloneIn silicoOther

    In computer calculations, GHRP‑6 UV spectra had approximately 20 nm error relative to experimental values.

    In plain wordsComputer calculations of GHRP‑6 ultraviolet spectra differed from experimental values by approximately 20 nm.

    Peptide
    GHRP-6
    Outcome
    Not applicableUV spectrum prediction error
    Study

    n: not reported in source

    Outcome group
    Analytical methods and detection · Pharmacology

    Measurements

    Spectral error
    ≈ 20 nm
    calculated versus experimental

    Source sentences

    Summary
    For polypeptide (oxytocin and GHRP-6), both UV and fluorescence spectra were obtained, and the errors between the calculated and experimental values approximately were 20 nm.
    1 context sentence
    Summary · context
    A workable approach named xTB-sTDDFT was selected to investigate the excited-state spectra of oxytocin (135 atoms), GHRP-6 (120 atoms) and insulin (793 atoms).

    In this study, GHRP-6 was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking GHRP-6.

  6. 06Computer modelNot a test of GHRP-6 aloneIn silicoOther

    In computer calculations, GHRP‑6 fluorescence spectra had approximately 20 nm error relative to experimental values.

    In plain wordsComputer calculations of GHRP‑6 fluorescence spectra differed from experimental values by approximately 20 nm.

    Peptide
    GHRP-6
    Outcome
    Not applicableFluorescence spectrum prediction error
    Study

    n: not reported in source

    Outcome group
    Analytical methods and detection · Pharmacology

    Source sentences

    Summary
    For polypeptide (oxytocin and GHRP-6), both UV and fluorescence spectra were obtained, and the errors between the calculated and experimental values approximately were 20 nm.
    1 context sentence
    Summary · context
    A workable approach named xTB-sTDDFT was selected to investigate the excited-state spectra of oxytocin (135 atoms), GHRP-6 (120 atoms) and insulin (793 atoms).

    In this study, GHRP-6 was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking GHRP-6.

  7. 07Computer modelNot a test of Oxytocin aloneIn silicoOther

    In computer calculations, oxytocin UV spectra had approximately 20 nm error relative to experimental values.

    In plain wordsComputer calculations of oxytocin ultraviolet spectra differed from experimental values by approximately 20 nm.

    Peptide
    Oxytocin
    Outcome
    Not applicableUV spectrum prediction error
    Study

    n: not reported in source

    Outcome group
    Analytical methods and detection · Pharmacology

    Source sentences

    Summary
    For polypeptide (oxytocin and GHRP-6), both UV and fluorescence spectra were obtained, and the errors between the calculated and experimental values approximately were 20 nm.
    1 context sentence
    Summary · context
    A workable approach named xTB-sTDDFT was selected to investigate the excited-state spectra of oxytocin (135 atoms), GHRP-6 (120 atoms) and insulin (793 atoms).

    In this study, Oxytocin was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking Oxytocin.

  8. 08Computer modelNot a test of Oxytocin aloneIn silicoOther

    In computer calculations, oxytocin fluorescence spectra had approximately 20 nm error relative to experimental values.

    In plain wordsComputer calculations of oxytocin fluorescence spectra differed from experimental values by approximately 20 nm.

    Peptide
    Oxytocin
    Outcome
    Not applicableFluorescence spectrum prediction error
    Study

    n: not reported in source

    Outcome group
    Analytical methods and detection · Pharmacology

    Source sentences

    Summary
    For polypeptide (oxytocin and GHRP-6), both UV and fluorescence spectra were obtained, and the errors between the calculated and experimental values approximately were 20 nm.
    1 context sentence
    Summary · context
    A workable approach named xTB-sTDDFT was selected to investigate the excited-state spectra of oxytocin (135 atoms), GHRP-6 (120 atoms) and insulin (793 atoms).

    In this study, Oxytocin was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking Oxytocin.

AI wrote and checked these results. AI can make mistakes, so check important results against the source.

Version history

PepBank keeps every version of the data on this study. Status changes from Retraction Watch, Europe PMC and Crossref are listed with their source.

  1. Version 3Current

    21 Oct 2026, 15:58 UTC

    Study results updated

  2. Version 2

    9 Oct 2026, 03:13 UTC

    Study data updated · source update from Europe PMC

  3. Version 1

    9 Oct 2026, 02:49 UTC

    First added · source update from Europe PMC

Subjects

Terms as the source lists them.

PepBank is a research reference. Talk to a doctor before you use any peptide.