In patients with hip or knee replacements, the body's own LL‑37 was up to 20 times higher in synovial membranes from periprosthetic joint infection than from aseptic loosening or primary arthroplasty.
In plain wordsThe body's own LL‑37 was much higher in joint tissue from infected joint replacements than in uninfected joint tissue.
- Peptide
- LL-37
- Outcome
- IncreaseLL-37 in synovial membrane in PJI
- Study
n = 25
- Comparator
- Aseptic loosening or primary arthroplasty
- Outcome group
- Inflammation markers · Infection
Source sentences
The AMPs LL-37 and HBD-3 were significantly elevated (up to 20×) in synovial membranes from PJI compared to aseptic loosening or primary arthroplasty.
1 context sentence(design, population, supporting numbers)
consecutive patients with total hip (THR) and knee (TKR) replacements were included undergoing primary arthroplasty (n = 8), surgical revision due to aseptic loosening (n = 9) and septic arthroplasty with coagulase-negative staphylococci (n = 8) according to the criteria of the Musculoskeletal Infection Society (MSIS)
This result measures the body's own LL-37. Nobody was given the peptide. It is not evidence about taking it.