Skip to content

Study · Animal study (in vivo) · beagle dog · 2020

6 results

Ultra-sensitive quantification of the therapeutic cyclic peptide bremelanotide utilizing UHPLC-MS/MS for evaluation of its oral plasma pharmacokinetics.

Sauter M, Uhl P, Burhenne J, Haefeli WE

Journal of pharmaceutical and biomedical analysis27 Mar 2020Cited by 5 (Europe PMC)

Summary

The text of this summary is not shown here, because the article license does not allow reuse. Read it at the source (opens in a new tab)

Text rights: Publisher copyright. Results still quote short attributed sentences.

Results from this study6

1 result from studies that gave the peptide. No result from this study comes from people.

  1. 01AnimalAnimal study (in vivo)Pharmacokinetics

    After oral administration to beagle dogs, plasma bremelanotide concentrations indicated minimal oral absorption.

    In plain wordsIn dogs, very little bremelanotide entered the blood after it was given by mouth.

    Outcome
    Not applicableOral plasma bremelanotide absorption
    Study

    beagle dogn: not reported in source

    Outcome group
    Pharmacokinetics · Pharmacology
    Studied dose
    Dose not stated · oralAs given in this study (beagle dog).

    Source sentences

    Summary
    The ultra-sensitive assay was applied to the quantification of bremelanotide plasma concentrations after oral administration to beagle dogs, which indicated minimal oral absorption.

Studies that did not test the peptide alone5

In this study, Bremelanotide (PT-141) was a lab tool or a carrier, part of a mix, or the subject of a lab method. These results are not evidence about taking Bremelanotide (PT-141).

  1. 02LabNot a test of Bremelanotide (PT-141) aloneOther designOther

    A validated UHPLC-MS/MS assay quantified bremelanotide in 100 μL of plasma with a lower limit of quantification of 10 pg/mL (9.8 pM).

    In plain wordsResearchers built a very sensitive lab test that measures tiny amounts of bremelanotide in blood plasma.

    Outcome
    Not applicableUHPLC-MS/MS assay lower limit of quantification
    Study

    n: not reported in source

    Outcome group
    Analytical methods and detection · Pharmacology

    Measurements

    LLOQ
    10 pg/mL
    plasma
    LLOQ
    9.8 pM
    plasma

    Source sentences

    Summary
    we established a UHPLC-MS/MS assay with an LLOQ of 10 pg/mL (9.8 pM)

    In this study, Bremelanotide (PT-141) was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking Bremelanotide (PT-141).

  2. 03LabNot a test of Bremelanotide (PT-141) aloneOther designOther

    The bremelanotide assay was linear over 10-10,000 pg/mL with correlation coefficients above 0.99.

    In plain wordsIn lab tests, the bremelanotide assay gave results that tracked concentration closely over its calibrated range.

    Outcome
    Not applicableAssay linearity
    Study

    n: not reported in source

    Outcome group
    Analytical methods and detection · Pharmacology

    Measurements

    Calibrated range lower limit
    10 pg/mL
    plasma
    Correlation coefficient
    0.99
    calibration

    Source sentences

    Summary
    The calibrated concentration range of 10-10,000 pg/mL was linear showing correlation coefficients > 0.99.

    In this study, Bremelanotide (PT-141) was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking Bremelanotide (PT-141).

  3. 04LabNot a test of Bremelanotide (PT-141) aloneOther designOther

    Within the calibrated range, interday and intraday accuracy of the bremelanotide assay was 88.9-100.0 % with precision below 8 %.

    In plain wordsIn lab tests, the bremelanotide assay was accurate and repeatable within its calibrated range.

    Outcome
    Not applicableAssay accuracy and precision in calibrated range
    Study

    n: not reported in source

    Outcome group
    Analytical methods and detection · Pharmacology

    Measurements

    Accuracy
    88.9 to 100%
    interday and intraday
    Precision
    < 8%
    interday and intraday

    Source sentences

    Summary
    In the calibrated range, interday and intraday accuracy ranged from 88.9-100.0 % with corresponding precision < 8 %.

    In this study, Bremelanotide (PT-141) was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking Bremelanotide (PT-141).

  4. 05LabNot a test of Bremelanotide (PT-141) aloneOther designOther

    At the lower limit of quantification, the bremelanotide assay had accuracy of 93.6-100.8 % with precision below 11 %.

    In plain wordsIn lab tests, the bremelanotide assay stayed accurate and repeatable at its lowest measurable level.

    Outcome
    Not applicableAssay accuracy and precision at LLOQ
    Study

    n: not reported in source

    Outcome group
    Analytical methods and detection · Pharmacology

    Measurements

    Accuracy
    93.6 to 100.8%
    LLOQ
    Precision
    < 11%
    LLOQ

    Source sentences

    Summary
    Accuracy at the LLOQ ranged from 93.6-100.8 % with corresponding precision < 11 %.

    In this study, Bremelanotide (PT-141) was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking Bremelanotide (PT-141).

  5. 06LabNot a test of Bremelanotide (PT-141) aloneOther designOther

    A dilution quality control showed accurate quantification of 10-fold diluted plasma samples, extending the assay to 100,000 pg/mL.

    In plain wordsIn lab tests, diluted plasma samples were still measured accurately, so the assay covers higher bremelanotide concentrations too.

    Outcome
    Not applicableDilution QC accuracy and precision
    Study

    n: not reported in source

    Outcome group
    Analytical methods and detection · Pharmacology

    Measurements

    Accuracy
    99.4%
    10-fold diluted plasma
    Precision
    < 6%
    10-fold diluted plasma

    Source sentences

    Summary
    Because of the validity of a dilution QC that showed accurate quantification of 10-fold diluted plasma samples (accuracy 99.4 %, precision < 6 %), the assay is suitable for bremelanotide quantification in its effective concentration range up to 100,000 pg/mL.

    In this study, Bremelanotide (PT-141) was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking Bremelanotide (PT-141).

AI wrote and checked these results. AI can make mistakes, so check important results against the source.

Version history

PepBank keeps every version of the data on this study. Status changes from Retraction Watch, Europe PMC and Crossref are listed with their source.

  1. Version 2Current

    9 Oct 2026, 18:17 UTC

    Study results updated

  2. Version 1

    9 Oct 2026, 03:04 UTC

    First added · source update from Europe PMC

Subjects

Terms as the source lists them.

PepBank is a research reference. Talk to a doctor before you use any peptide.