In healthy volunteers, tetracosactide produced mean serum cortisol of 30.3 (±7.83) μg/dl at 30 minutes.
In plain wordsIn healthy volunteers, serum cortisol averaged 30.3 μg/dl at 30 minutes after tetracosactide.
- Peptide
- Cosyntropin
- Outcome
- Not applicableSerum cortisol at 30 minutes
- Study
n = 15
- Outcome group
- Diagnostic test performance · Endocrine and hormones
Measurements
- Serum cortisol
- 30.3 μg/dl
- 30 minutes
- Reported variability
- 7.83 μg/dl
- 30 minutes
Source sentences
Mean serum cortisol values with tetracosactide were 30.3 (±7.83) μg/dl and 31.27 (±7.36) μg/dl at 30 and 60 minutes, respectively.
1 context sentence(design, population, supporting numbers)
Fifteen healthy volunteers were enrolled. Serum cortisol was measured at 0 minute in all subjects and at 30 and 60 minutes after tetracosactide hexaacetate 250 μg intravenously. Four weeks later, serum cortisol level was measured at 0 minute and at 30 and 60 minutes following 24 units of porcine seq…
In this study, Cosyntropin was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking Cosyntropin.