Skip to content

Study · Not a test of the peptide alone · 2017

2 results

A statistical method to calculate blood contamination in the measurement of salivary hormones in healthy women.

Behr GA, Patel JP, Coote M, Moreira JCF, Gelain DP, Steiner M, Frey BN

Clinical biochemistry16 Dec 2016Cited by 8 (Europe PMC)

Summary

The text of this summary is not shown here, because the article license does not allow reuse. Read it at the source (opens in a new tab)

Text rights: Publisher copyright. Results still quote short attributed sentences.

Results from this study2

No result from this study comes from a test of the peptide.

Studies that did not test the peptide alone2

In this study, Oxytocin was a lab tool or a carrier, part of a mix, or the subject of a lab method. These results are not evidence about taking Oxytocin.

  1. 01HumanNot a test of Oxytocin aloneObservational studyOther

    In healthy women, salivary transferrin levels, a marker of blood contamination, correlated positively with salivary oxytocin measured by immunoassay.

    In plain wordsIn healthy women, blood contamination in saliva samples was linked to higher measured salivary oxytocin.

    Peptide
    Oxytocin
    Outcome
    IncreaseSalivary transferrin correlation with salivary oxytocin
    Study

    n = 38

    Outcome group
    Analytical methods and detection · Endocrine and hormones

    Source sentences

    Summary
    but they were positively correlated with salivary testosterone, progesterone and oxytocin (p<0.05).
    1 context sentence
    Summary · context
    Saliva and serum samples were collected from 38 healthy, medication-free women (mean age=33.8±7.3yr.; range=19-45).

    In this study, Oxytocin was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking Oxytocin.

  2. 02HumanNot a test of Oxytocin aloneObservational studyOther

    In healthy women, the analysis suggested avoiding saliva samples with transferrin above 0.64 mg/dl for salivary oxytocin analysis.

    In plain wordsIn healthy women, saliva samples with transferrin above a set level should be avoided when measuring oxytocin.

    Peptide
    Oxytocin
    Outcome
    Not applicableTransferrin threshold for salivary oxytocin analysis
    Study

    n = 38

    Outcome group
    Analytical methods and detection · Endocrine and hormones

    Measurements

    Transferrin threshold
    0.64 mg/dl
    salivary oxytocin analysis

    Source sentences

    Summary
    Our analyses suggest that transferrin levels higher than 0.80, 0.92 and 0.64mg/dl should be avoided for testosterone, progesterone and oxytocin salivary analyses, respectively.
    1 context sentence
    Summary · context
    Saliva and serum samples were collected from 38 healthy, medication-free women (mean age=33.8±7.3yr.; range=19-45).

    In this study, Oxytocin was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking Oxytocin.

AI wrote and checked these results. AI can make mistakes, so check important results against the source.

Version history

PepBank keeps every version of the data on this study. Status changes from Retraction Watch, Europe PMC and Crossref are listed with their source.

  1. Version 2Current

    11 Oct 2026, 01:30 UTC

    Study results updated

  2. Version 1

    9 Oct 2026, 02:49 UTC

    First added · source update from Europe PMC

Subjects

Terms as the source lists them.