All four polyclonal antibodies against MGF C-terminal peptides identified their corresponding antigen in mouse serum by reverse-phase protein microarray.
In plain wordsIn lab tests, all four antibodies made against MGF pieces found their matching target in mouse serum.
- Peptide
- MGF / PEG-MGF
- Outcome
- Not applicableAntibody recognition of antigen in mouse serum
- Study
n: not reported in source
Mouse serum, reverse-phase protein microarray- Outcome group
- Analytical methods and detection · Pharmacology
Source sentences
It was found that all the antibodies could identify their corresponding antigen in mouse serum by reverse-phase protein microarray, in particular, Ab-K01 showed the highest affinity among them and might be a potential tool for the detection of antibody affinity.
1 context sentence(design, population, supporting numbers)
Four polyclonal antibodies (Ab-K01, Ab-B01, Ab-B02 and Ab-K02) against MGF C-terminal peptides were generated, purified and evaluated by western blot, ELISA and reverse-phase protein microarray, respectively.
In this study, MGF / PEG-MGF was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking MGF / PEG-MGF.