Skip to content

Study · Not a test of the peptide alone · 2001

3 results

Determination of growth hormone-releasing hexapeptide by reversed-phase high-performance liquid chromatography with electrochemical detection.

Choi SJ, Lee HY, Kim SB, Kim JH, Lee SS, Yoo SD, Lee KC, Lee HS

Journal of chromatography. B, Biomedical sciences and applications1 Apr 2001Cited by 1 (Europe PMC)

Summary

The text of this summary is not shown here, because the article license does not allow reuse. Read it at the source (opens in a new tab)

Text rights: Publisher copyright. Results still quote short attributed sentences.

Results from this study3

No result from this study comes from a test of the peptide.

Studies that did not test the peptide alone3

In this study, GHRP-6 was a lab tool or a carrier, part of a mix, or the subject of a lab method. These results are not evidence about taking GHRP-6.

  1. 01LabNot a test of GHRP-6 aloneIn vitro (cell-free)Other

    In an analytical assay, GHRP‑6 separated on a reversed-phase CN column with an acetonitrile-phosphate mobile phase.

    In plain wordsIn lab tests, the assay separated GHRP‑6 on a reversed-phase column.

    Peptide
    GHRP-6
    Outcome
    Not applicableChromatographic separation
    Study

    n: not reported in source

    HPLC with electrochemical detection
    Outcome group
    Analytical methods and detection · Pharmacology

    Source sentences

    Summary
    GHRP-6 was separated on a reversed-phase CN column with 37% acetonitrile in 100 mM phosphate buffer (pH 7.0) as the mobile phase.

    In this study, GHRP-6 was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking GHRP-6.

  2. 02LabNot a test of GHRP-6 aloneIn vitro (cell-free)Other

    In an analytical assay, the optimum GHRP‑6 oxidation signal occurred at 0.85 V versus Ag/AgCl.

    In plain wordsIn lab tests, GHRP‑6 gave its best oxidation signal at 0.85 V versus Ag/AgCl.

    Peptide
    GHRP-6
    Outcome
    Not applicableOptimum oxidation signal
    Study

    n: not reported in source

    HPLC with electrochemical detection
    Outcome group
    Analytical methods and detection · Pharmacology

    Measurements

    Oxidation potential
    0.85 V
    versus Ag/AgCl

    Source sentences

    Summary
    The optimum electrochemical oxidation signal was obtained at 0.85 V vs. Ag/AgCl in a glassy carbon working electrode due to two electroactive tryptophans and a histidine residue.

    In this study, GHRP-6 was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking GHRP-6.

  3. 03LabNot a test of GHRP-6 aloneIn vitro (cell-free)Other

    In serum samples, the GHRP‑6 assay operated over a concentration range of 5 to 100 ng/ml.

    In plain wordsIn lab tests, the assay measured GHRP‑6 in serum over a range of 5 to 100 ng/ml.

    Peptide
    GHRP-6
    Outcome
    Not applicableSerum analytical concentration range
    Study

    n: not reported in source

    HPLC with electrochemical detection
    Outcome group
    Analytical methods and detection · Pharmacology

    Measurements

    Concentration range
    5 to 100 ng/ml
    serum analyte

    Source sentences

    Summary
    Solid-phase extraction using octadecyl cartridges was optimized for sample cleanup of GHRP-6 from serum samples and the method was successfully applied over the concentration range of 5 to 100 ng/ml of analyte. reserved.

    In this study, GHRP-6 was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking GHRP-6.

AI wrote and checked these results. AI can make mistakes, so check important results against the source.

Version history

PepBank keeps every version of the data on this study. Status changes from Retraction Watch, Europe PMC and Crossref are listed with their source.

  1. Version 2Current

    21 Oct 2026, 15:58 UTC

    Study results updated

  2. Version 1

    9 Oct 2026, 03:13 UTC

    First added · source update from Europe PMC

Subjects

Terms as the source lists them.

PepBank is a research reference. Talk to a doctor before you use any peptide.