Skip to content

Study · Non-randomized trial · 2000

4 results

Value of peptide receptor scintigraphy using (123)I-vasoactive intestinal peptide and (111)In-DTPA-D-Phe1-octreotide in 194 carcinoid patients: Vienna University Experience, 1993 to 1998.

Raderer M, Kurtaran A, Leimer M, Angelberger P, Niederle B, Vierhapper H, Vorbeck F, Hejna MH, Scheithauer W, Pidlich J, Virgolini I

Journal of clinical oncology : official journal of the American Society of Clinical Oncology1 Mar 2000Cited by 42 (Europe PMC)

Summary

The text of this summary is not shown here, because the article license does not allow reuse. Read it at the source (opens in a new tab)

Text rights: Publisher copyright. Results still quote short attributed sentences.

Results from this study4

4 results from studies that gave the peptide. 4 results from people.

  1. 01HumanNon-randomized trialEfficacy outcome

    In carcinoid patients, 32 of 38 (82%) scans with (123)I-VIP were positive in primary or recurrent tumors, fewer than with (111)In-DTPA-D-Phe(1)-octreotide (35 of 38).

    In plain wordsIn carcinoid patients, the VIP tracer scan was positive in 82% of scans for primary or recurrent tumours, fewer than the octreotide tracer scan.

    Outcome
    Not applicablePositive 123I-VIP scans in primary or recurrent carcinoid tumors
    Study

    n: not reported in source

    Comparator
    (111)In-DTPA-D-Phe(1)-octreotide scan
    Outcome group
    Diagnostic imaging · Cancer
    Studied dose
    Dose not stated

    Measurements

    Positive scans
    32 scans
    primary or recurrent tumors, 123I-VIP
    Positive scans
    82%
    primary or recurrent tumors, 123I-VIP

    Source sentences

    Summary
    35 (93%) of 38 versus 32 (82%) of 38 scans being positive in primary or recurrent tumors
    1 context sentence
    Summary · context
    One hundred ninety-four patients with a verified or clinically suspected diagnosis of a carcinoid tumor were injected with (111)In-DTPA-D-Phe(1)-OCT for imaging purposes, while 133 patients underwent scanning with both (123)I-VIP and (111)In-DTPA-D-Phe(1)-OCT in random order.
  2. 02HumanNon-randomized trialEfficacy outcome

    In carcinoid patients, 53 of 65 (82%) scans with (123)I-VIP were positive in patients with metastatic sites, fewer than with (111)In-DTPA-D-Phe(1)-octreotide (58 of 65).

    In plain wordsIn carcinoid patients, the VIP tracer scan was positive in 82% of scans for patients with metastases, fewer than the octreotide tracer scan.

    Outcome
    Not applicablePositive 123I-VIP scans in patients with metastatic sites
    Study

    n: not reported in source

    Comparator
    (111)In-DTPA-D-Phe(1)-octreotide scan
    Outcome group
    Diagnostic imaging · Cancer
    Studied dose
    Dose not stated

    Measurements

    Positive scans
    53 scans
    metastatic sites, 123I-VIP
    Positive scans
    82%
    metastatic sites, 123I-VIP

    Source sentences

    Summary
    58 (90%) of 65 versus 53 (82%) of 65 being positive in patients with metastatic sites
    1 context sentence
    Summary · context
    One hundred ninety-four patients with a verified or clinically suspected diagnosis of a carcinoid tumor were injected with (111)In-DTPA-D-Phe(1)-OCT for imaging purposes, while 133 patients underwent scanning with both (123)I-VIP and (111)In-DTPA-D-Phe(1)-OCT in random order.
  3. 03HumanNon-randomized trialEfficacy outcome

    In carcinoid patients with symptoms but otherwise negative work-ups, four of 16 (25%) scans with (123)I-VIP were positive, fewer than with (111)In-DTPA-D-Phe(1)-octreotide (seven of 16).

    In plain wordsIn carcinoid patients with symptoms but negative other tests, the VIP tracer scan was positive in 25% of scans, fewer than the octreotide tracer scan.

    Outcome
    Not applicablePositive 123I-VIP scans in symptomatic patients with otherwise negative work-ups
    Study

    n: not reported in source

    Comparator
    (111)In-DTPA-D-Phe(1)-octreotide scan
    Outcome group
    Diagnostic imaging · Cancer
    Studied dose
    Dose not stated

    Measurements

    Positive scans
    25%
    symptoms, otherwise negative work-up, 123I-VIP

    Source sentences

    Summary
    seven (44%) of 16 versus four (25%) of 16 being positive in patients with symptoms but otherwise negative work-ups.
    1 context sentence
    Summary · context
    One hundred ninety-four patients with a verified or clinically suspected diagnosis of a carcinoid tumor were injected with (111)In-DTPA-D-Phe(1)-OCT for imaging purposes, while 133 patients underwent scanning with both (123)I-VIP and (111)In-DTPA-D-Phe(1)-OCT in random order.
  4. 04HumanNon-randomized trialEfficacy outcome

    Overall, 25 of 103 (25%) scans with (123)I-VIP showed additional lesions not seen on conventional imaging, fewer than with (111)In-DTPA-D-Phe(1)-octreotide (43 of 158).

    In plain wordsThe VIP tracer scan found extra lesions, not seen on standard imaging, in 25% of scans. The octreotide tracer scan found them in 41%.

    Outcome
    Not applicableAdditional lesions seen with 123I-VIP scans
    Study

    n: not reported in source

    Comparator
    (111)In-DTPA-D-Phe(1)-octreotide scan
    Outcome group
    Diagnostic imaging · Cancer
    Studied dose
    Dose not stated

    Measurements

    Scans with additional lesions
    25 scans
    123I-VIP
    Scans with additional lesions
    25%
    123I-VIP

    Source sentences

    Summary
    Overall, additional lesions not seen on conventional imaging were imaged in 43 (41%) of 158 versus 25 (25%) of 103 scans with (111)In-DTPA-D-Phe(1)-OCT and (123)I-VIP, respectively.
    1 context sentence
    Summary · context
    One hundred ninety-four patients with a verified or clinically suspected diagnosis of a carcinoid tumor were injected with (111)In-DTPA-D-Phe(1)-OCT for imaging purposes, while 133 patients underwent scanning with both (123)I-VIP and (111)In-DTPA-D-Phe(1)-OCT in random order.

AI wrote and checked these results. AI can make mistakes, so check important results against the source.

Version history

PepBank keeps every version of the data on this study. Status changes from Retraction Watch, Europe PMC and Crossref are listed with their source.

  1. Version 2Current

    9 Oct 2026, 19:08 UTC

    Study results updated

  2. Version 1

    9 Oct 2026, 12:41 UTC

    First added · source update from Europe PMC

Subjects

Terms as the source lists them.

PepBank is a research reference. Talk to a doctor before you use any peptide.