A radioimmunoassay for DSIP measured DSIP-like material in body fluids with a minimum detectable concentration of 0.1 ng/ml.
In plain wordsIn lab tests, a new assay could detect DSIP-like material in body fluids down to 0.1 ng/ml.
- Outcome
- Not applicableRadioimmunoassay detection limit for DSIP
- Study
n: not reported in source
radioimmunoassay- Outcome group
- Receptor activity and mechanism · Pharmacology
Measurements
- Minimum detectable concentration
- 0.1 ng/ml
- standard DSIP
Source sentences
The assay allows measurement of DSIP-like material in body fluids with a minimum detectable concentration of 0.1 ng/ml standard DSIP (10 pg/tube).
In this study, Delta sleep-inducing peptide (DSIP) was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking Delta sleep-inducing peptide (DSIP).