Skip to content

Study · Not a test of the peptide alone · 1988

6 results

Biophysical characteristics of oxytocin secretory granules isolated from ovine corpora lutea.

Rice GE

The Journal of endocrinology1 Feb 1988Cited by 2 (Europe PMC)

Summary

The text of this summary is not shown here, because the article license does not allow reuse. Read it at the source (opens in a new tab)

Text rights: Publisher copyright. Results still quote short attributed sentences.

Results from this study6

No result from this study comes from a test of the peptide.

Studies that did not test the peptide alone6

In this study, Oxytocin was a lab tool or a carrier, part of a mix, or the subject of a lab method. These results are not evidence about taking Oxytocin.

  1. 01LabNot a test of Oxytocin aloneEx vivo tissueOther

    Oxytocin-containing secretory granules isolated from ovine corpora lutea had an isopycnic sedimentation density of 1.03 g/ml.

    In plain wordsIn lab tests, oxytocin-containing granules from sheep ovaries had a density of 1.03 g/ml.

    Peptide
    Oxytocin
    Outcome
    Not applicableIsopycnic sedimentation density of luteal oxytocin granules
    Study

    Sheepn: not reported in source

    Secretory granules isolated from ovine corpora lutea
    Outcome group
    Peptide structure and chemistry · Reproductive and sexual health

    Measurements

    Isopycnic sedimentation density
    1.03 g/ml
    ovine luteal granules

    Source sentences

    Summary
    The isopynic sedimentation density (1.03 +/- 0.003 g/ml) and sedimentation coefficient (1670 S, 0.32 mol sucrose/l, 4 degrees C) of these granules have been estimated.
    1 context sentence
    Summary · context
    Luteal oxytocin-containing secretory granules have been isolated and characterized in terms of their physicochemical parameters.

    In this study, Oxytocin was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking Oxytocin.

  2. 02LabNot a test of Oxytocin aloneEx vivo tissueOther

    Oxytocin-containing secretory granules isolated from ovine corpora lutea had a sedimentation coefficient of 1670 S.

    In plain wordsIn lab tests, oxytocin-containing granules from sheep ovaries had a sedimentation coefficient of 1670 S.

    Peptide
    Oxytocin
    Outcome
    Not applicableSedimentation coefficient of luteal oxytocin granules
    Study

    Sheepn: not reported in source

    Secretory granules isolated from ovine corpora lutea
    Outcome group
    Peptide structure and chemistry · Reproductive and sexual health

    Measurements

    Sedimentation coefficient
    1670 S
    0.32 mol sucrose/l, 4 degrees C

    Source sentences

    Summary
    The isopynic sedimentation density (1.03 +/- 0.003 g/ml) and sedimentation coefficient (1670 S, 0.32 mol sucrose/l, 4 degrees C) of these granules have been estimated.
    1 context sentence
    Summary · context
    Luteal oxytocin-containing secretory granules have been isolated and characterized in terms of their physicochemical parameters.

    In this study, Oxytocin was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking Oxytocin.

  3. 03LabNot a test of Oxytocin aloneEx vivo tissueOther

    The calculated average diameter of oxytocin-containing luteal granules was 258 nm.

    In plain wordsIn lab tests, oxytocin-containing granules from sheep ovaries had an average diameter of 258 nm.

    Peptide
    Oxytocin
    Outcome
    Not applicableAverage vesicle diameter of luteal oxytocin granules
    Study

    Sheepn: not reported in source

    Secretory granules isolated from ovine corpora lutea
    Outcome group
    Peptide structure and chemistry · Reproductive and sexual health

    Measurements

    Average vesicle diameter
    258 nm
    ovine luteal granules

    Source sentences

    Summary
    Based upon these estimates, the average vesicle diameter (258 +/- 17 nm) and vesicle weight (9.92 +/- 0.67 fg/vesicle) were calculated.
    1 context sentence
    Summary · context
    Luteal oxytocin-containing secretory granules have been isolated and characterized in terms of their physicochemical parameters.

    In this study, Oxytocin was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking Oxytocin.

  4. 04LabNot a test of Oxytocin aloneEx vivo tissueOther

    The calculated vesicle weight of oxytocin-containing luteal granules was 9.92 fg per vesicle.

    In plain wordsIn lab tests, oxytocin-containing granules from sheep ovaries weighed 9.92 fg each.

    Peptide
    Oxytocin
    Outcome
    Not applicableVesicle weight of luteal oxytocin granules
    Study

    Sheepn: not reported in source

    Secretory granules isolated from ovine corpora lutea
    Outcome group
    Peptide structure and chemistry · Reproductive and sexual health

    Measurements

    Vesicle weight
    9.92 fg/vesicle
    ovine luteal granules

    Source sentences

    Summary
    Based upon these estimates, the average vesicle diameter (258 +/- 17 nm) and vesicle weight (9.92 +/- 0.67 fg/vesicle) were calculated.
    1 context sentence
    Summary · context
    Luteal oxytocin-containing secretory granules have been isolated and characterized in terms of their physicochemical parameters.

    In this study, Oxytocin was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking Oxytocin.

  5. 05LabNot a test of Oxytocin aloneEx vivo tissueOther

    The exchangeable water content of oxytocin-containing luteal granules was 58.2%.

    In plain wordsIn lab tests, oxytocin-containing granules from sheep ovaries had an exchangeable water content of 58.2%.

    Peptide
    Oxytocin
    Outcome
    Not applicableExchangeable water content of luteal oxytocin granules
    Study

    Sheepn: not reported in source

    Secretory granules isolated from ovine corpora lutea
    Outcome group
    Peptide structure and chemistry · Reproductive and sexual health

    Measurements

    Exchangeable water content
    58.2%
    ovine luteal granules

    Source sentences

    Summary
    The exchangeable water content (58.2%) of these granules was determined using density gradients prepared with deuterium oxide.
    1 context sentence
    Summary · context
    Luteal oxytocin-containing secretory granules have been isolated and characterized in terms of their physicochemical parameters.

    In this study, Oxytocin was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking Oxytocin.

  6. 06LabNot a test of Oxytocin aloneEx vivo tissueOther

    Luteal oxytocin-containing granules were 1.3 times greater in diameter than neurohypophysial granules, with otherwise similar physicochemical characteristics.

    In plain wordsIn lab tests, sheep ovary oxytocin granules were 1.3 times wider than pituitary granules but otherwise similar.

    Peptide
    Oxytocin
    Outcome
    Not applicableGranule diameter, luteal versus neurohypophysial granules
    Study

    Sheepn: not reported in source

    Secretory granules isolated from ovine corpora lutea
    Comparator
    Neurohypophysial peptide-containing granules
    Outcome group
    Peptide structure and chemistry · Reproductive and sexual health

    Measurements

    Diameter ratio
    1.3 times
    luteal versus neurohypophysial granules

    Source sentences

    Summary
    Luteal oxytocin-containing granules displayed similar physicochemical characteristics to those reported for neurohypophysial peptide-containing granules, with the exception of particle size. Luteal granules were 1.3 times greater in diameter than neurohypophysial granules.
    1 context sentence
    Summary · context
    Luteal oxytocin-containing secretory granules have been isolated and characterized in terms of their physicochemical parameters.

    In this study, Oxytocin was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking Oxytocin.

AI wrote and checked these results. AI can make mistakes, so check important results against the source.

Version history

PepBank keeps every version of the data on this study. Status changes from Retraction Watch, Europe PMC and Crossref are listed with their source.

  1. Version 2Current

    11 Oct 2026, 20:03 UTC

    Study results updated

  2. Version 1

    9 Oct 2026, 02:52 UTC

    First added · source update from Europe PMC

Subjects

Terms as the source lists them.