In a parathymosin radioimmunoassay using a rabbit antiserum, thymosin alpha‑1 showed no significant cross-reactivity.
In plain wordsIn lab tests, a new parathymosin assay did not react significantly with thymosin alpha‑1.
- Peptide
- Thymosin alpha-1
- Outcome
- No significant changeCross-reactivity of thymosin alpha 1 with parathymosin antiserum
- Study
n: not reported in source
Radioimmunoassay with rabbit antiserum- Outcome group
- Analytical methods and detection · Pharmacology
Source sentences
Neither thymosin alpha 1 nor prothymosin alpha show significant cross-reactivity with this antiserum.
1 context sentence(design, population, supporting numbers)
To evaluate the content of parathymosin in tissues and fluids, we have developed a radioimmunoassay using an antiserum raised in a rabbit against parathymosin isolated from rat liver.
In this study, Thymosin alpha-1 was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking Thymosin alpha-1.