The HPLC method accurately determined oxytocin in injection solutions containing 1 I.U. per ml using injection volumes up to 750 microliter.
In plain wordsIn lab testing, the HPLC method measured low-concentration oxytocin in injection solutions.
- Peptide
- Oxytocin
- Outcome
- Not applicableHPLC determination of oxytocin in injection solutions
- Study
n: not reported in source
- Outcome group
- Analytical methods and detection · Pharmacology
Measurements
- Oxytocin concentration
- 1 I.U. (international unit) per ml
- injection solutions
- Injection volume
- ≤ 750 microliter
- injection volume
Source sentences
The use of injection volumes up to 750 microliter permits accurate determination of, e.g., oxytocin in injection solutions containing only 1 I.U. (international unit) per ml.
1 context sentence(design, population, supporting numbers)
A high-performance liquid chromatographic (HPLC) method is described for determining oxytocin, lypressin and other nonapeptides and their by-products in liquid and solid pharmaceutical dosage forms.
In this study, Oxytocin was a lab tool or a carrier, part of a mix, or the subject of a lab method. This result is not evidence about taking Oxytocin.